Type CTV Specifications

 

 

 

Inlet

NPT

Outlet

NPT

Operating pressure PSIG

Cv

Weight

lbs

Body Material

1/2

1/2

200

2.0

0.75

304 SS

                        Flow Coefficient   CV at set point     

             Note: For saturated steam systems only. 

  for  ∆P[psig]   1/2 P[inlet] 

                                           

lbs/hr[steam] = 1.84Cv(∆P + 14.7)

Maximum flow rate – valve fully open

 

To Order: 

 

1/2

CTV

?

B

D

T

 

                                          Complete the model number by inserting the desired condensate discharge temperature in °F.

 

 

.

Actual CTV temperature setting depends upon the requirements and variables of your specific application.

 

For example:

A 180°F setting is ideal for most winterization systems; a 240°F setting is suggested for most process tracing and drip legs; for impulse and sample lines, a 60°, 100° or 120°F setting could be used.  Other temperature set points available.

 

Guarantee:

We will repair or replace on a no-charge basis, F.O.B. Willow Grove, PA. Ogontz valves returned to us within 18 months if found to be defective in material or workmanship

 

 

 

Back to CTV Page

Back to Ogontz Home Page

2835 Terwood Road, Willow Grove, PA 19090 USA 800-523-2478 email: info@ogontz.com